When to Remove Lifting Equipment From Service: What takes it off the hook, and what happens next

When lifting gear shows a discard defect, it comes out of service immediately. What happens next depends on the equipment and the defect: some components are condemned for good, and some assemblies can be repaired with approved parts and re-certified. What never happens is defective gear going back into service because it passed a proof load.
This article sets out the removal and discard triggers for wire rope, chain, synthetic slings and rigging hardware, what quarantine actually looks like on site, and what happens to gear once it has been condemned.
Key terms
Three decisions, not one
Most sites run these together and it causes real problems. They are separate calls, made at different moments, often by different people.
The failure mode is a site that does the first step and skips the second. Gear gets pulled off a job, put down somewhere out of the way, and is back in the rack a fortnight later because nobody tagged it and nobody remembers why it was set aside. Who is competent to make the third call is a separate question – we cover it in dogger vs qualified lifting inspector.
Triggers for immediate removal from service
Before the type-specific criteria, five conditions take any item of lifting equipment off the hook, whatever it's made of. Whether it's then repairable or condemned is the competent person's call – but it stops being used the moment any of these is found.
Any one of these is enough on its own. You don't need a second finding.
Wire rope and wire rope slings
Wire rope deteriorates through abrasive wear, wire breaks, loss of lubrication, corrosion and consolidation of the core. Most of that is invisible from the outside.
The triggers: broken wires exceeding the discard limit for the rope's construction, loss of rope diameter, wear on the individual outer wires, corrosion, kinking, birdcaging, high stranding, crushed or flattened sections, damaged thimbles, and extended lay.
Two diameter figures, and they are not the same thing. This is the most misread pair of numbers in wire rope inspection.
| Criterion | Figure | What is being measured |
|---|---|---|
| Loss of rope diameter | More than 5% of nominal | The overall diameter of the rope, against its nominal new diameter |
| Wear on individual wires | More than 33% | The diameter of the individual outer wires – not the rope |
The "one-third" figure gets quoted constantly and misapplied to the rope. A rope that had lost a third of its overall diameter would be long past anything resembling serviceable – it would have collapsed internally. Five per cent is the rope figure. Thirty-three per cent is the wire figure. Know which one you're measuring before you put a caliper on it.
A kink is the one that gets argued about on site. It is permanent. The strands have moved relative to each other and the load path through the rope is no longer what it was designed to be. A kinked rope can't be straightened back to rated condition and it can't be de-rated to a lower WLL. It is condemned.
From a Ranger inspection
Left: a rope with both kinking and broken wires. A certain number of broken wires is permitted, but the kink alone met the discard criteria – the rope didn't need to fail two tests. Right: corrosion along the full visible length.


Governing standards: AS 1666.2 for wire rope slings in service; AS 2759 for steel wire rope application and discard factors. [RANGER TO CONFIRM: AS 1666.2-2009 reconfirmed 2019 – check still current; confirm current AS 2759 edition]
The full breakdown – broken wire counts, measuring diameter properly, internal corrosion and magnetic rope testing – is in wire rope discard criteria.
Alloy chain slings
Chain is the most forgiving of the four and the easiest to over-trust. It looks indestructible, so it gets left in service on visual impressions rather than measurement.
The triggers: any permanent stretch or elongation, wear at the link bearing points exceeding 10%, nicks and gouges in the links, twisted or bent links, heat or chemical exposure, and damage or displacement of end fittings – hooks, latches, master links, connectors.
Stretch is binary. There is no allowable amount of permanent elongation in an alloy chain sling – any measurable stretch means the chain has been loaded beyond its design, and it comes out. Wear is different: it builds up normally at the bearing points where links articulate, and 10% of the original dimension is the limit.
Both need a measurement, not a look. Measure a worn link with vernier callipers at the bearing surface, against the nominal dimension for that chain size. Nobody can reliably tell a link that has lost 8% from one that has lost 12% by eye.
From a Ranger inspection
Corrosion and deep gouges across several links, and one link in the middle of the run visibly twisted. The twist is the tell – that's overload, or a lift made around a sharp edge. One twisted link takes the whole assembly out of service, not just the link.



Governing standards: AS 3775.1 for product; AS 3775.2:2014 incorporating Amendment 1:2015 for care and use; components to AS 3776. AS 3775 covers Grade T(80) and Grade V(100) – Grade 120 chain sits outside those tables and is assessed against the manufacturer's criteria. Replacement chain and components: lifting chain.
Synthetic slings – flat webbing and roundslings
Synthetics fail fastest and show it most clearly, which is the one advantage they have. The damage is on the surface where you can see it, provided someone is looking.
Flat webbing slings go on: acid or caustic burns, melting or charring anywhere on the surface, snags, punctures, tears or cuts, broken or worn stitching, damage to load-bearing fibres, wear or elongation beyond the manufacturer's limit, distortion of fittings, and cuts to the selvedge. A small selvedge cut costs a disproportionate amount of strength, because that edge carries the sling's structure.
Roundslings go on: any tear in the outer cover that exposes the load-bearing core, cuts, snags or abrasion to the cover, heat or chemical damage, and damage to end fittings. The cover isn't structural – it's there to protect the core and to show you damage. Once the core is visible, the sling is finished. There is no assessment to make.
A note on surface condition. Fading or bleaching toward white may indicate UV degradation. Surface fuzzing can also come from ordinary abrasion, and shouldn't automatically be read as UV damage – furry edges aren't necessarily a problem unless they affect the stitching. What matters is damage to the load-bearing fibres, damage to stitching, loss of material, and hardening. Apply the relevant sling standard and the manufacturer's criteria rather than judging by appearance alone.
From a Ranger inspection
A roundsling torn through the outer and inner cover, core protruding to the surface – immediate removal, condemned. And flat slings with severe transverse abrasion and selvedge damage, from being fed under a load and dragged over steel. That pattern comes from a method problem, not a sling problem.



Governing standards: AS 1353:2026 for flat synthetic-webbing slings – manufacture, care and use – which replaced AS 1353.1 and AS 1353.2 on 25 June 2026. AS 4497:2018 for synthetic fibre roundslings. Range: synthetic slings.
Rigging hardware and lifting points
Shackles, links, rings, swivels, turnbuckles, hooks, eyebolts, hoist rings, wire rope clips, wedge sockets, rigging blocks and fixed lifting points.
The triggers common to all of them: bent, twisted, distorted, stretched, elongated, cracked or broken load-bearing components; excessive nicks, gouges, pitting or corrosion; heat damage including weld spatter; and missing or illegible rated load identification.
Wear limits are component-specific. Shackles are withdrawn where crown or pin wear exceeds 10% of the original diameter. Similar limits apply to some hooks and to chain components. But 10% isn't a universal discard rule for every lifting accessory – swivels, turnbuckles, sockets, blocks and engineered lifting points are each assessed against their applicable standard and the manufacturer's criteria.
Eyebolts carry a 10% figure too, but it's measured differently. Under AS 2317.1:2018 (clause 4.13.5), an eyebolt comes out once wear, corrosion, nicks or gouges reduce any section by 10% in any plane, measured against the manufacturer's dimensions. It's discarded outright for distortion, a bent shank, thread damage, illegible markings or heat exposure. More on eyebolt ratings and inspection in eyebolt WLL and angular loading.
If you take one number away, take the shackle one. It's the item most people own most of, and it wears at the crown and the pin bearing surface – the two places nobody looks. The ways shackles get damaged in the first place are in shackle misuse.
From a Ranger inspection
Shackles bent and elongated by overload. A shackle and hook distorted by the same event – shackle bent, pin loose (a side-loading signature), hook throat opened past tolerance. And a pad eye welded to a vessel's working deck, corroded until the weld and the eye had started to come away. A pad eye is part of the structure rather than part of the kit, so nobody inspects it the way they inspect a sling. It was still in use.



Governing standards: AS 2741 for shackles, AS 2317.1:2018 for collared eyebolts and eyenuts, AS 4991 for lifting devices. Range: shackles.
Quarantine: what it actually looks like
Removing gear from service means nothing if it can be picked back up. Quarantine is four steps and they take about two minutes.
Tag it. Physically attached, stating the item is out of service and the date. A tag isn't a substitute for segregation – it's what stops the item being used in the twenty minutes before it gets moved.
Segregate it. A designated area, locked or at minimum nowhere near serviceable gear. Not the back of the ute. Not the corner of the container where the good slings live.
Record it. Item ID, date removed, who removed it, what was observed. This is the part that gets skipped, and the part that matters six months later when someone asks what happened to asset 4471.
Get the determination. A competent person assesses it: return to service, repair and re-certify, or condemn.
If the answer is condemned, the item doesn't go in the skip intact. Inspection records for your gear can live in the Ranger Inspection Gateway.
Condemned gear: render it unusable
This is Ranger's position and it isn't universal in the industry: condemned lifting gear should be rendered permanently unusable before disposal. The method depends on the item. [RANGER TO CONFIRM: destruction method by equipment type – confirm this matches what Ranger technicians actually do]
Where thermal cutting is used, normal hot work controls apply.
The reason isn't theoretical. Condemned gear that goes into a skip intact comes back out of the skip. It gets picked up for a quick job that "isn't really lifting", sold on, or taken home. A shackle condemned for 15% crown wear doesn't look condemned to someone who finds it in a bin. It looks like a free shackle.
Rendering the item unusable is the only disposal method that closes that loop. Once it's destroyed, synthetics go out as general waste and metallics go to scrap steel.
Who makes the determination
The competent person. Under the model WHS framework, that means someone who has acquired – through training, qualification or experience – the knowledge and skills to carry out the task.
The confusion sits in assuming a dogging licence covers all of it. It doesn't, but it covers more than most content on this subject admits. A dogging licence includes selecting and pre-use inspecting lifting gear, and identifying, isolating, labelling and reporting defective items. That's a real competency and it's the front line of this whole process.
What it doesn't establish on its own is competency to perform every type of periodic inspection, certification, repair assessment or technical examination across all classes of lifting equipment. Those are separate competencies, assessed separately. Ranger's own policy is to use formally assessed, LEEA-qualified inspectors for periodic inspection and certification work.
The records you should keep
WHS Regulation 213 requires plant maintenance, inspection and, where necessary, testing to be carried out by a competent person. It doesn't itself set a general record retention period for lifting accessories.
Regulation 237 contains mandatory record-keeping requirements for plant that needs design or item registration – those records are kept while the plant is used, or until control of it is relinquished.
For other plant and lifting equipment, keeping inspection, maintenance and disposal records is good practice, and may also be required by the applicable standard, the manufacturer, the client or the site procedure. A discard record should capture:
In a failure investigation, the records are the first thing anyone asks for. A site that can produce a clean trail is in a very different position to one that can only say the gear "was replaced at some point".
Questions we get asked on site
Can a sling that failed inspection be re-tested and put back in service?
It depends on the finding. If the item has been condemned, no – proof loading degraded structure doesn't restore capacity and can make it worse. But not every inspection failure is a condemnation. An assembly with a damaged component can often be repaired by replacing that component with an approved one, then inspected, tested or re-certified as the applicable standard requires. What is never acceptable is returning defective gear to service on the strength of a proof load alone.
Who is allowed to condemn lifting equipment?
A competent person. Anyone can remove an item from service – that's the point of the first decision – but deciding what happens next takes the competency to make that call.
What do I do with a sling that has no legible tag?
Remove it from service. Without a legible WLL and identification there is no rated capacity to work to. Whether it can be re-identified and re-tagged depends on the equipment type, whether its identity and history are recoverable, the applicable standard, and a competent person's assessment. If it can't be identified, it's condemned.
Do I have to destroy condemned gear, or can I just throw it out?
Nothing in the standards requires destruction. Ranger's position is to render it permanently unusable anyway, because intact condemned gear in a skip has a habit of finding its way back into use. Cut the load-bearing sections and destroy the identification separately.
How long do I keep the records?
There is no blanket retention period under the model WHS Regulations for ordinary lifting slings and accessories. Registered plant has specific requirements under Regulation 237. For everything else, follow the applicable standard, the manufacturer, your jurisdiction, the contract and the site procedure. [RANGER TO CONFIRM: does Ranger want to state its own retention period here? If not, delete this marker]
One link in a four-leg chain sling is damaged. Do I lose the whole assembly?
The assembly comes out of service. Whether it's repairable depends on the component and the damage – a damaged hook can often be replaced, a stretched or twisted chain leg generally can't. The assembly doesn't go back on the hook until a competent person has made that call and the assembly has been re-certified.
Is 10% wear the rule for all rigging hardware?
No, and this is a common misreading. Ten per cent of original diameter is the criterion for shackle crown and pin wear, and similar limits apply to some hooks and chain components. Eyebolts have their own 10% section-loss limit under AS 2317.1:2018, applied to any section rather than one measured diameter. Swivels, turnbuckles, sockets, blocks and engineered lifting points each have their own criteria under their own standards.
Getting it assessed properly
Most of these criteria can be applied on site by a competent person with vernier callipers, a good light and the right standard in front of them. The ones that can't are the internal failures – internal corrosion and wire breakage in rope, and fatigue in alloy components that hasn't yet reached the surface.
Ranger has been inspecting, testing and certifying lifting and rigging equipment since 1998, across NSW, QLD, VIC and SWQ, and holds NATA accreditation for specified inspection and testing activities. Every defect photographed in this article came off a real inspection – a vessel deck, a mine site, a workshop rack. The gear in those photos was in service the day before our inspector picked it up.
If your removal and discard decisions are currently being made by whoever happens to notice, that's the gap worth closing first.
Standards and regulatory references
Standards current as at October 2026.
Ranger Lifting Rigging Safety has inspected, tested, certified and supplied lifting and rigging equipment across NSW, QLD, VIC and SWQ since 1998. Our inspectors are trained and credentialed specifically for equipment examination, working to the relevant Australian Standards within a NATA-accredited framework.